Page 30 of 87
©Retrotec Inc. 2015
Additional panels, including a Small-X panel, can be purchased to increase the maximum doorway height that the
modular panel is capable of filling.
Overall outside dimensions (OD) for the Modular panels:
Model:
PN201
Type of Panel:
Hard Panel (Single Fan)
Width (min/max):
32” – 48.75” (81 - 124 cm)
Height (min/max):
76.5” - 87” (194 - 221 cm)
Panel Case (included):
31” x 30” x 7” (79 x 76 x 18 cm)
PN210R Large X-Panel: 27 ¾”H x 29 5/8”W closed, 51”W open
PN211 XY Panel: 19 ½”H x 29 5/8”W closed, 52”W x 30” open
PN207 Large Fill-in Sheet for Fan Panel: 27”H x 17 ½”W OD
PN208 Small Fill-in Sheet for Fan Panel: 26”H x 4 ½”W OD
A Field Verification Plate and a Blanking Plate are available for insertion in the holes of the Modular Door Panel, to
run a verification of the calibration of the system and cover any non-needed holes in Fan Panels. See details in
Appendix C.
A Weather Strip replacement kit is also available.
3.2.1. Modular Door Panel Instructions
For detailed instructions on installing the Modular Door Panel, see the Modular Door Panel Quick Guide.
To install the Modular Door Panels
1. Unpack the panels. The Fan Panel is installed first. Place it in the doorway, touching the ground. All panels
should expand towards the door hinges. The panels can be expanded by pulling the yellow cords tight, and
then securing the cord on the cleat. Do not secure the yellow cords on the Velcro, to hold the straps tight.
The Velcro is only meant to hold the straps against the panels. Attach the fan strap.