Table of Contents
1 Installation instructions ................................................................................ 4
1.1 Minimum system requirements ................................................................................................... 4
1.2 Download FanTestic Integrity ....................................................................................................... 4
1.3 Start FanTestic Integrity ................................................................................................................ 8
1.4 Enter a license key ........................................................................................................................ 8
1.5 Select a testing standard to use .................................................................................................. 10
1.6 Change language for user interface (and generated reports) .................................................... 11
1.7 Choose formula used to calculate peak pressure ....................................................................... 12
1.8 Change parameters used for running the program – (advanced operation) ............................. 13
2 Calculators are accessed in the Tools menu ................................................ 15
2.1 Calculate Pressure Relief Vent needed for system design .......................................................... 15
3 Perform an enclosure integrity test ............................................................. 17
3.1 Set up Door Fan equipment ........................................................................................................ 17
3.2 Begin a new test in the software to record Door Fan test.......................................................... 17
3.3 Input background test information ............................................................................................. 17
3.3.1 Test and technician information ............................................................................................................ 18
3.3.2 Equipment ............................................................................................................................................. 18
3.3.3 Enter building, enclosure and extinguishing agent details .................................................................... 20
3.4 Enter enclosure integrity test air leakage data – for Enclosure Hold Time Analysis .................. 28
3.4.1 Enter recorded data from a Door Fan test ............................................................................................ 29
3.4.2 Leakage area calculated from door fan test entries .............................................................................. 32
3.4.3 Enter leakage results already calculated from a previous Door Fan test .............................................. 33
3.4.4 Leakage area used directly as entered .................................................................................................. 33
3.5 Enter optional Lower Leaks Test for Enclosure Hold Time Analysis ........................................... 34
3.6 Enter values from an optional Upper Leaks Test ........................................................................ 35
3.7 Calculate and see hold time analysis results .............................................................................. 35
3.7.1 Click the calculate button to see results ................................................................................................ 35
3.7.2 Graph the test data and results ............................................................................................................. 35
3.8 Total Enclosure Leakage and Lower leaks test results ................................................................ 36
3.9 Hold time analysis results Summary ........................................................................................... 37
FanTestic Integrity
Retrotec’s latest Enclosure Integrity Test software
Calculation of agent hold time or extended discharge rate, and peak pressure with required vent area,
based on measured or estimated enclosure leakage
Venting calculator to determine size of required pressure relief vent even before leakage is measured
Comprehensive, informative, customizable reports output to Microsoft Word
Automatic updates over the Internet
Calculations fully compliant with the ISO 14520 standard (2006 edition), and some previous editions
Small and versatile data storage of results using an open XML format (fxml)