QG130 Page 1 of 8
Made in Everson, WA USA
rev-2014-08-05
QuickGuide
DU200 DucTester
Flex Duct
DM-2 gauge
(Batteries included)
Umbilical
Flange
Low-Range Ring
Mid-Range Ring
DucTester
Grill Mask
QuickGuides
Battery Charger
Tubing
Accessory Kit
Unpack, connect DM-2 gauge
Check boxes for each step.
Remove everything from the case.
Install 4 NiMH AA batteries.*
Plug in the battery charger.
Press [On], then [Exit], to display
the battery indicator.
Charge for 18 hrs.
Connect yellow, green and blue tube
to gauge.
Slide gauge into the clear sleeve and
velcro Umbilical to case.
Gauge remains connected
like this for all tests.
* If changing to non-rechargeable batteries, disable
charging in [Setup] menu. For steps see:
Quick Guide DM-2 mark II Digital Gauge, page 1
www.retrotec.com Sales & Support: (855)738-7683 Internaonal: (604)732-0142
Seitenansicht 0
1 2 3 4 5 6 7 8

Inhaltsverzeichnis

Seite 1 - DU200 DucTester

QG130 Page 1 of 8 Made in Everson, WA USA rev-2014-08-05QuickGuide DU200 DucTesterFlex DuctDM-2 gauge(Batteries included)UmbilicalFlangeLow-Range Rin

Seite 2 - Prepare the DM-2 gauge

Step 1: Prepare ducts and house□ Seal all supply and return grills/registers, including any exterior air inlets, with Grill Mask or tape.□ Open al

Seite 3 - Step 4: Conduct test

□ Press [On] twice to get to main screen. □ Adjust fan speed knob clockwise until “PrA” reaches test pressure. □ If not possible, go t

Seite 4 - Hold display and Jog speed

Flow at the induced pressure is the simplest result.Mode = “Flow”Units = “CFM”Flow per ft2 (sq ft) is required in some states, such as WA.Mode = “Fl

Seite 5 - We’re here to help!

Page 5 of 8Free Training VideosWe’re here to help!Check out Retrotec’s YouTube page, with all the videos you’ll need to help you setup, run, or troubl

Seite 6 - Method# 1

Page 6 of 8To measure the air leakage from the duct system to outdoors requires both a DucTester and a Blower Door system. The Blower Door depressuriz

Seite 7 - Using the optional Flow Hood

□ Connect Flex Duct to fan exhaust.□ Check that tubing is connected the same as for depressurize test (step 3).□ Conduct test (step 4).Duct Leaka

Seite 8 - Field check system monthly

Tubing Accessory Kit35 ft (10 m) of blue, red, yellow and green 1/4 inch (12mm) outside diameter tubing. Static Pressure Probe, 4 inch (100 mm) x 1/8